Temperature is the main factor affecting the life of the capacitor, the temperature rise of the bus capacitor is mainly affected by the ripple current flowing through, the operating
frequency spectra, the converter stage usually has much lower frequency ripple current content than the inverter stage. Therefore, let us first examine the converter stage by itself, and initially
Additionally, ZSI can reliably work with a wide range of DC input voltage generated from PV sources. So, ZSIs are widely implemented for distributed generation systems and electric
Two-stage single-phase photovoltaic inverters exhibit a second-harmonic ripple at the dc-link voltage, which can cause variations in the terminal voltage of the photovoltaic
Grid converters play a central role in renewable energy conversion. Among all inverter topologies, the current source inverter (CSI) provides many advantages and is, therefore, the focus of ongoing research.
Abstract: When an existing photovoltaic (PV) system is upgraded to a residential PV/battery system, the single-phase PV inverter under both input conditions of battery and PV should be
Due to power time-varying characteristic of a single phase photovoltaic (PV) grid-connected inverter in grid side, its front-end dc/dc converter tends to draw a large ac ripple current with
inverters; 2) high-frequency switching ripple with any power converter in a photovoltaic system; and 3) perturbations and tracking errors in maximum-power-point tracking systems. Index
A novel active control method is proposed for mitigating the input current ripple, which adopts double-channel current feedbacks including an additional ripple current feedback
The current ripple prediction should also consider nonideal effects in the system. Section 4.6 mainly analyzes the influence of common-mode circuit and nonlinear inductance of
Fig. 2 shows a typical inverter positive half-cycle current waveform that is composed of a fundamental current component (i b) and a ripple current component (i r). If a smaller coupled inductance was chosen, the ripple
Due to the absence of the insulated transformer, the non-insulated photovoltaic (PV) inverter possesses excellent properties such as small size, light weight, etc. However, the
dc-link current and voltage ripple calculations in voltage source inverters by considering the reverse recovery of the antiparallel diodes. The impact of the diode reverse recovery transient
Under steady statecondition, when the current reaches the peak value,the ripple current is most serious. So the current transient process in a switching period at the current peak is the key
Two-stage single-phase photovoltaic inverters exhibit a second-harmonic ripple at the dc-link voltage, which can cause variations in the terminal voltage of the photovoltaic
A repetitive controller based dual-mode control method for PV powered single-phase buck-boost inverter under nonlinear load scenario manages to significantly mitigate ripple components in
Due to power time-varying characteristic of a single phase photovoltaic (PV) grid-connected inverter in grid side, its front-end dc/dc converter tends to draw a large ac ripple
the peak-to-peak output current ripple has not been emphasised yet. In [14], the current ripple trajectory in α−β coordinates for the case of dual-inverter-fed open-end winding load
This manuscript proposes a novel approach for determining phase and neutral-current-ripple RMS in grid-connected four-leg inverters with the neutral inductor. The harmonic pollution is determined for any arbitrary pulse
However, the use of full-bridge inverters inevitably generates a 120 Hz ripple voltage in the DC-Link. In addition, there is reactive power in the grid, the power factor of the grid is reduced due to the reactive component. Therefore, it was modeled as an RL load to realize the reactive power of the grid.
However, compensating for the reactive current increases the 120 Hz ripple voltage component that occurs in the DC-Link. The increase in the 120 Hz ripple voltage follows the compensation of the reactive component, and increases the distortion rate of the grid current, thereby degrading the overall performance of the PV power generation system.
Moreover, a grid current distortion reduction scheme is proposed to reduce the effect of 120 Hz ripple voltage component. The validity of the proposed scheme is investigated through simulations and experiments. A photovoltaic power generation system converts solar energy into electrical energy without causing secondary pollution. [ 1]
Therefore, when a PV panel is integrated into a three-phase AC grid, a voltage source inverter (VSI) or a current source inverter (CSI) is needed for power conversion , , . The VSI usually needs a front-stage DC/DC converter to boost the DC voltage . On the other hand, the one-stage CSI adopts only an inductor to boost the voltage .
However, it can be seen that the magnitude of the ripple voltage of the compensation value ( VDC_Comp) waveform for inverter control decreased, which reduced the ripple component of the inverter active reference ( Iinv_qe_ref ), which can be observed in Fig. 11.
This study proposes a power factor reduction compensation scheme that occurs when driving a RL load in a single-phase photovoltaic system. Moreover, a grid current distortion reduction scheme is proposed to reduce the effect of 120 Hz ripple voltage component. The validity of the proposed scheme is investigated through simulations and experiments.
We are deeply committed to excellence in all our endeavors.
Since we maintain control over our products, our customers can be assured of nothing but the best quality at all times.